Availability: | |
---|---|
:Housing Style Classification
:Panel Style Classification
:Product Classification
:Working Power Supply Power Supply (Transformer)
M | M1 | M2 |
Multi-function meter | Multi-display meter | Voltage and current patrol meter |
A1 | V1 | VA |
Current single display meter | Voltage single display meter | Voltage and current double display meter |
A3 | V3 | |
Three-phase Ammeter | Three-phase voltmeter |
T1 | T2
|
AC220V ; 50/60HZ | AC380V ; 50/60HZ |
S1 | S2
|
AC/DC 20~60V | AC/DC 80~260V |
R | Blank |
RS485 (MODBUS) | Non Communication |
:Control Output
T | M |
main control output SSR (DC12V) | main control switch output (relay) |
V | A |
voltage analog output (0~10V) | current analog output (4~20mA) |
1 | 2 |
1-wayout output (single relay) upper limit output | 2-way output (double relay) upper limit+lower limit output |
0 or empty | |
No control output |
:Input Signal (CT/ CT1/ PT/ PT1/ BTS1)
CT:
Current measurement range | The measuring range can be expanded |
0~10A | determined by the parameters of external transformer |
Variable ratio is adjustable | |
the default value is1 |
CT1:
Current measurement range (fixed) | External transformer can be hooked up outside |
0~100A | Transformation ratio of 1000/1 ( variable ratio is not adjustable ) |
PT | PT1 |
Voltage Transformer (built-in) | Voltage Transformer (external) |
BTS1 | |
Current Divider (external) |
:Control Output Remarks For Special Measuring Range (When the transformer is external, the variable ratio is marked here.)
:Function Customization (The function code is a 3-bit combination number)
Working Environment
Air Pressure | Relative Humidity |
86 - 106kPa | 45 - 85% RH |
Main Technical Parameters
M1: The factory default of M1 multi-display meter is ammeter.When there is no signal input at the current detection end and there is signal input at the voltage detection end, the meter will automatically switch to voltmeter. If there is signal input at both ends, the preferred option is ammeter.
Maximum Power Consumption Of Instrument : 6W
Frequency Range Of Measurement Input Signal : 10~99.9Hz (factory default)
The Sampling Rate : about 100mS
The Measurement Accuracy : + 0.5%
Environment : the temperature is -30~55℃ and the humidity is ≤ 85% RH without corrosion.
Contact Capacity Of Alarm Output Relay : 3A-AC250V/DC30V
Product Appearance And Installing Size (mm)
M2 -zhengfangx | 48×48×66 | 46×46 |
M5▢▢ - | 48×96×66 | 46×92 |
M6 ▢▢ - | 72×72×66 | 67×67 |
M8 ▢▢ - | 80×80×66 | 76×76 |
Panel Style
Dark Border Panel
Dark Panel
:Housing Style Classification
:Panel Style Classification
:Product Classification
:Working Power Supply Power Supply (Transformer)
M | M1 | M2 |
Multi-function meter | Multi-display meter | Voltage and current patrol meter |
A1 | V1 | VA |
Current single display meter | Voltage single display meter | Voltage and current double display meter |
A3 | V3 | |
Three-phase Ammeter | Three-phase voltmeter |
T1 | T2
|
AC220V ; 50/60HZ | AC380V ; 50/60HZ |
S1 | S2
|
AC/DC 20~60V | AC/DC 80~260V |
R | Blank |
RS485 (MODBUS) | Non Communication |
:Control Output
T | M |
main control output SSR (DC12V) | main control switch output (relay) |
V | A |
voltage analog output (0~10V) | current analog output (4~20mA) |
1 | 2 |
1-wayout output (single relay) upper limit output | 2-way output (double relay) upper limit+lower limit output |
0 or empty | |
No control output |
:Input Signal (CT/ CT1/ PT/ PT1/ BTS1)
CT:
Current measurement range | The measuring range can be expanded |
0~10A | determined by the parameters of external transformer |
Variable ratio is adjustable | |
the default value is1 |
CT1:
Current measurement range (fixed) | External transformer can be hooked up outside |
0~100A | Transformation ratio of 1000/1 ( variable ratio is not adjustable ) |
PT | PT1 |
Voltage Transformer (built-in) | Voltage Transformer (external) |
BTS1 | |
Current Divider (external) |
:Control Output Remarks For Special Measuring Range (When the transformer is external, the variable ratio is marked here.)
:Function Customization (The function code is a 3-bit combination number)
Working Environment
Air Pressure | Relative Humidity |
86 - 106kPa | 45 - 85% RH |
Main Technical Parameters
M1: The factory default of M1 multi-display meter is ammeter.When there is no signal input at the current detection end and there is signal input at the voltage detection end, the meter will automatically switch to voltmeter. If there is signal input at both ends, the preferred option is ammeter.
Maximum Power Consumption Of Instrument : 6W
Frequency Range Of Measurement Input Signal : 10~99.9Hz (factory default)
The Sampling Rate : about 100mS
The Measurement Accuracy : + 0.5%
Environment : the temperature is -30~55℃ and the humidity is ≤ 85% RH without corrosion.
Contact Capacity Of Alarm Output Relay : 3A-AC250V/DC30V
Product Appearance And Installing Size (mm)
M2 -zhengfangx | 48×48×66 | 46×46 |
M5▢▢ - | 48×96×66 | 46×92 |
M6 ▢▢ - | 72×72×66 | 67×67 |
M8 ▢▢ - | 80×80×66 | 76×76 |