What is an emergency stop push button switch?
Emergency stop switch, also known as emergency stop switch, emergency switch, kill switch or emergency button, emergency stop button switch, is a fail-safe control switch that provides safety protection for machinery and equipment. People who use machines.
specify the following requirements: Emergency stop switches must be highly visible in colour, labeling and shape for easy operation in emergency situations. So the button has to be a red mushroom head with an arrow, emergency or stop symbol.
Common sizes for mushroom heads are 29mm, 30mm, 40mm or 60mm. The direct operating mechanism must be set on a normally closed contact and have a self-holding function. It requires a twist, pull or key to release the electrical contacts to allow the machine to restart.
Emergency Stop Button (E-stop for short) is an emergency stop device, usually used in mechanical and automation systems to prevent accidental injury or equipment damage. The following are the main functions and features of the emergency stop button in production:
effect:
Emergency stop: When a dangerous or unexpected event occurs, press the emergency stop button to stop the machine or equipment immediately to prevent further injury or equipment damage.
Convenient operation: The emergency stop button is usually located in an easily accessible position of the machine or equipment, and is generally easy to identify and operate.
System safety: By using the emergency stop button, it can reduce the negligence and error of the system operator and help ensure the safety of the system.
Protection equipment: the emergency stop button can automatically cut off the power supply in case of equipment overload, overheating, overvoltage, etc., so as to protect the equipment from damage.
characteristic:
Independent control: The emergency stop button is usually not related to the control of other equipment, and has an independent circuit to ensure that the machine or equipment can be stopped immediately under any circumstances.
Easy reset: Once the emergency stop button is pressed, it must be reset manually to restart the machine or equipment. This can prevent the machine or equipment from restarting in an unsafe state.
Reliability: The emergency stop button must be reliable, operable, and highly reliable and durable to ensure that it can work normally when needed.
Standardization: The color and shape of emergency stop button are generally standardized to facilitate identification and operation, and comply with relevant safety standards and regulations.
The core of industrial control is the control of the motor, the core of the motor control is the contactor, the conventional component of the contactor coil control is the button switch, today we will take the button switch of GQELE Electric as an example, briefly introduce the function of the button switch in the second Function, use and installation in control loops.
Installation category
This series of buttons are φ22mm panel mounting buttons, and the panel mounting holes are φ22.7mm~φ22.3mm. Standard buttons can use 1~6mm thick mounting panels, and economical buttons can use 1~4mm thick mounting panels.
Signal indicator light, a device that uses light to monitor the working or position status of circuits and electrical equipment. It is also the most intuitive and unique monitoring component in automation equipment. The main function is usually used to reflect the working state of the circuit (with or without electricity), the working state of electrical equipment (running, outage or test) and position state (closed or disconnected), etc. To remind the operator to deal with the fault in time, or operate a certain function to complete the relevant action.
Push button switch, also known as control button (referred to as button), is a low-voltage electrical appliance that can be manually reset and generally automatically reset. Buttons are usually used in circuits to issue start or stop commands to control the on and off of electric coil currents such as electromagnetic starters, contactors, and relays.
Main functions: generally used in control circuits with AC and DC voltages below 440V and currents less than 5A, generally do not directly manipulate the main circuit, but can also be used in interconnected circuits. In order to control the operation of the equipment, stop, pause or reset and other functions.
Push button switch, also known as control button (referred to as button), is a low-voltage electrical appliance that can be manually reset and generally automatically reset. Buttons are usually used in circuits to issue start or stop commands to control the on and off of electric coil currents such as electromagnetic starters, contactors, and relays.
The push button switch is an electrical appliance that is used to turn on and off small current circuits, which is pressed to act and released to reset. It is generally used in control circuits with AC and DC voltages below 440V and currents less than 5A. Generally, it does not directly control the main circuit, but can also be used in interconnected circuits.
In actual use, in order to prevent misoperation, the buttons are usually marked with different marks or painted with different colors to distinguish them. The colors are red, yellow, blue, white, black, green, etc. Generally, red indicates operation in a "stop" or "dangerous" situation; green indicates "start" or "connect". The emergency stop button must use a red mushroom head button. The button must have a metal protective retaining ring, and the retaining ring should be higher than the button cap to prevent accidental touch of the button and cause malfunction. The material of the button plate and button box where the button is installed must be metal and connected to the general ground bus bar of the machine.
Use Maintenance Edit
(1) The button should be checked frequently to remove the dirt on it. Due to the small distance between the contacts of the button, after many years of use or when the seal is not good, dust or various stages of oil emulsion will flow in, which will cause insulation reduction or even a short circuit accident. In this case, insulation and cleaning must be carried out, and corresponding sealing measures must be taken.
(2) When the button is used in a high-temperature place, it is easy to deform and age the plastic, causing the button to loosen and causing a short circuit between the wiring screws. According to the situation, a fastening ring can be added to tighten it during installation, and an insulating plastic tube can also be added to the wiring screw to prevent loosening.
(3) The button with the indicator light is easy to deform the plastic lampshade due to the heat of the bulb for a long time, which makes it difficult to replace the bulb. Therefore, it is not suitable to be used in places where the power-on time is long; if you want to use it, you can properly reduce the voltage of the bulb to prolong its service life.
If poor contact is found, the cause should be found out: if the contact surface is damaged, it can be repaired with a fine file; if there is dirt or soot on the contact surface, it should be wiped clean with a clean cotton cloth dipped in solvent; if the contact spring If it fails, it should be replaced; if the contact is severely burned, the product should be replaced.